文章信息/Info

Title:
 A new on-line fault diagnosis method of inter-turn short circuit fault in rotor winding of hydro-generator
作者:
 武玉才1 马倩倩1 蔡波冲1 唐劲飞2
 ( 1. 华北电力大学电气与电子工程学院,河北保定071003; 2. 国网国际发展有限公司发展策划部,北京100031)
Author(s):
 WU Yu-cai1 MA Qian-qian1 CAI Bo-chong1 TANG Jin-fei2
 ( 1. School of Electrical and Electronic Engineering,North China Electric Power University,Baoding 071003,China;2. Development Planning Department,State Grid International Development Limited,Beijing 100031,China)
关键词:
水轮发电机 转子绕组匝间短路 U 型检测线圈 感应电压差 在线诊断
Keywords:
 hydro-generator rotor winding inter-turn short-circuit U-type detection coil induced voltage difference on-line diagnosis
分类号:
TM 315
DOI:
10.15938/j.emc.2018.11.003
文献标志码:
A
摘要:
针对转子绕组匝间短路故障可引起水轮发电机机组较为强烈的振动,导致计划外停机的问题,以二滩水电站一台550 MW 水轮发电机为例,根据磁动势平衡原理,推导匝间短路前后发电机主磁场的变化规律,提出在水轮发电机定子铁心上安装U 型检测线圈,用以检测转子绕组匝间短路故障。根据发电机主磁场的运动规律,推导穿过U 型检测线圈的磁通表达式,进一步得到检测线圈的感应电动势。二维电磁场仿真证明U 型检测线圈的感应电压可以反映水轮发电机的转子绕组匝间短路程度,并能定位故障磁极位置,新型检测方法实现了对水轮发电机转子绕组匝间短路故障的在线诊断。
Abstract:
 Aiming at the problem that the rotor winding inter-turn short circuit fault can cause the hydrogenerator set to vibrate more violently,which leads to the unplanned downtime,taking a 550 MW hydroelectric generator at Ertan Hydropower Station as an example,according to the principle of magnetomotive force balance,the variation law of main magnetic field of the generator before and after inter turn-short circuit fault was deduced. A U-type detection coil was proposed to be installed around the stator core of
hydrogenerators,which could be used to detect the inter turn short circuit fault of rotor windings. According to the motion law of generator main magnetic field,the expression of flux passing through the detecting coil through U type was derived,and the induction electromotive force of the detecting coil was further obtained. The 2-D electromagnetic simulation proved that the induced voltage by U-type detection coil can reflect the short-circuit level of rotor windings in hydro-generators,and locate the faulty-pole position.
By using the new detection method the on-line diagnosis of the inter-turn short-circuit fault of the rotor winding in hydro generators is realized.

参考文献/References:

相似文献/References:

[1]霍菲阳,李伟力,王冬梅,等.大型水轮发电机阻尼条数对电磁参数和附加损耗的影响[J].电机与控制学报,2011,(05):89.
 HUO Fei-yang,LI Wei-li,WANG Dong-mei.Influence of damper winding on electromagnetic parameters and additional loss of large hydo-generator[J].,2011,(11):89.
[2]梁艳萍,孙洋,孙玉田,等.1000MW水轮发电机定子股线环流损耗分析计算[J].电机与控制学报,2011,(07):65.
 LIANG Yan-ping,SUN Yang,SUN Yu-tian.Calculation and analysis on circulating current losses in the stator bar strands of a 1000MW hydro-generator[J].,2011,(11):65.
[3]姚缨英,刘广.等效时谐耦合场分析水轮发电机负序运行能力[J].电机与控制学报,2011,(11):33.
 YAO Ying-ying,LIU Guang.Analysis of negative sequence ability of hydro-generator based on equivalent time-harmonic coupled finite-element method[J].,2011,(11):33.
[4]梁艳萍,吴磊,边旭,等. 基于多截面场路耦合法的大型水轮发电机定子线棒换位分析[J].电机与控制学报,2013,(08):63.
 LIANG Yang-ping,WU Lei,BIAN Xu.[J].,2013,(11):63.
[5]戈宝军,肖士勇,吕艳玲,等.水轮发电机定子绕组内部故障暂态电流研究[J].电机与控制学报,2014,18(03):40.
 GE Bao-jun,XIAO Shi-yong,L Yan-ling,et al.Transient current study of hydro-generator stator winding internal fault[J].,2014,18(11):40.

备注/Memo

备注/Memo:
 收稿日期: 2017 - 06 - 17
基金项目: 河北省自然科学基金( E2016502031) ; 中央高校基本科研业务费专项资金资助( 2017MS106)
作者简介: 武玉才( 1982—) ,男,博士,副教授,研究方向为电气设备状态监测与故障诊断;
马倩倩( 1992—) ,女,硕士研究生,研究方向为水轮发电机状态监测与故障诊断;
蔡波冲( 1990—) ,男,硕士研究生,研究方向为无刷励磁机状态监测与故障诊断;
唐劲飞( 1980—) ,男,硕士,高级工程师,研究方向为电网设备状态评价和分析诊断。