|本期目录/Table of Contents|

[1]吴新振,张 阳,赵永正.角接三相异步发电机单相带载稳态分析[J].电机与控制学报,2017,21(01):45-50.[doi:10.15938/j.emc.2017.01.007]
 WU Xin-zlien,ZHANG Yang,ZHAO Yong-zlieng.Steady-state analysis of three-phase self-excited induction generator supplying single-phase load[J].,2017,21(01):45-50.[doi:10.15938/j.emc.2017.01.007]
点击复制

角接三相异步发电机单相带载稳态分析(PDF)
分享到:

《电机与控制学报》[ISSN:1007-449X/CN:23-1 408/TM]

卷:
21
期数:
2017年01
页码:
45-50
栏目:
出版日期:
2017-01-01

文章信息/Info

Title:
Steady-state analysis of three-phase self-excited induction generator supplying single-phase load
作者:
吴新振 张 阳赵永正
?(1.青岛大学电气工程系,山东青岛266〇71 ;2.国网山东电力检修公司,山东济南250118)
Author(s):
WU Xin-zlien1 ZHANG Yang1 ZHAO Yong-zlieng2
?(1. Department of Electrical Engineering Qingdao University Qingdao 266071,China; 2. State Grid Shandong Electric Power Maintenance Company Jinan 250118,China)
关键词:
异步发电机单相负载稳态运行等值电路电容组合
Keywords:
induction generator single-phase load steady-state operation equivalent circuit capacitor combination
分类号:
TM 343
DOI:
10.15938/j.emc.2017.01.007
文献标志码:
A
摘要:
给出三角形接法三相自激异步发电机为单相负载供电时系统的连接方式,通过对系统中 独立节点电量关系的推导,将发电机基值频率下的正序和负序等值电路通过简单的阻抗元件连接,构成合成等值电路。根据 Kirchhoff 定律,以合成等值电路中回路阻抗模值为零作为系统稳态运行的条件和分析计算的基础。采用优化方法计算了不同电容组合下系统的负载电压,求取了负载电压一定时电机所需并联的电容组合,并根据不同稳压电容组合下系统的负序电流所占比重求得最佳平衡状态下的稳压电容值。计算值与实验值相互吻合,验证了该分析方法的有效性和准确性。
Abstract:
The circuit of a delta-connected three-j^hase self-excited induction generator supplying for a single-phase load was illustrated. Based on the boundary conditions of electric quantities in each node,the positive and negative sequence circuits reduced in base value of frequency were connected togetiier as the combined equivalent circuit. According to Kirchhoff ’ s Law,the loop impedance of t!ie combined e-quivalent circuit is supposed to be zero,which is regarded as the condition and basement for steady state analysis. Optimum metiiod was adopted in programming to calculate load voltages under diferent capaci-or combinations and the proper combinations for a given load voltage. The best combination for the most balanced operation witii the lowest ratio of negative sequence current was calculated. The calculated results are in good agreement wit!i experiment data,which verified the validity and accuracy of t!iis analysis method.

参考文献/References:

-

相似文献/References:

[1]张学广,徐殿国,李伟伟.双馈风力发电机三相短路电流分析[J].电机与控制学报,2008,(05):493.
 ZHANG Xue-guang,XU Dian-guo,LI Wei-wei.Analysis of three-phase short circuit current of doubly fed induction generator[J].,2008,(01):493.

备注/Memo

备注/Memo:
收稿日期:2015 -09 -07
基金项目:国家自然科学基金(51377086);国家自然科学基金(51677092)
作者简介:吴新振(1964—),男,博士,教授,博士生导师,研究方向为电机系统分析与控制;
张阳(1990—),男,硕士研究生,研究方向为电机运行分析;
赵永正(1989—),男,硕士,工程师,研究方向为电力系统分析与控制。